Elevator emergency plan summary, collection and forward to the people around!
2024-05-14
author:
Page view:
Elevator emergency plan summary, collection and forward to the people around!
2. After receiving the report, the security fire control room shall, on the one hand, know the location, number of trapped people, personnel situation and floor where the elevator is located through the monitoring system or interphone, and on the other hand, report to the manager of the security department through interphone and contact the maintenance unit for rescue.
3. After receiving the report, the manager of the security department immediately arrived in person or sent personnel to get in touch with the trapped passengers, comforted the passengers, asked the passengers to remain calm and wait patiently for help. Especially when the trapped passengers are frightened or very impatient and try to use extraordinary measures such as prying the door to escape, they should patiently warn the passengers not to panic and impatience, and not to take unnecessary actions blindly, so as not to expand the fault and cause danger. Note that in this process, the scene can never leave people, to keep dialogue with the trapped people, timely understanding of the trapped people's mood and health, and timely report the situation to the company's general manager or on-duty leader.
5. If the maintenance unit and the elevator maintenance company are unable to rescue or cannot be rescued within a short period of time, they should seek help from the public security department or the fire department as the case may be (the reasons and circumstances for seeking help should be explained). Before seeking help from the public security and fire department, the consent of the general manager or the on-duty leader of the company shall be obtained.
6. During the rescue process, if it is found that some of the trapped passengers are fainting or unconscious (especially the elderly or children), the medical staff should be notified immediately so that the trapped persons can be rescued.
7. After the trapped persons are rescued, the security manager or the foreman on duty should immediately express their condolences to them, understand their physical condition and needs, and ask them to provide their names, addresses, contact numbers and reasons for coming to the community. If the trapped person does not cooperate and leaves on his own, he should record it for the record.
8. After the trapped person is rescued, the elevator maintenance company should be asked to find out the cause of the failure immediately, and the normal operation can be restored after repair.
9. The manager of the security department or the foreman on duty shall record the incident in detail, including the time of receiving the report, the time of arrival of the security and maintenance personnel at the scene, the notification and arrival time of the elevator maintenance company, the rescue time of the trapped personnel, the basic situation of the trapped personnel, and the time for the elevator to resume normal operation. If there are public security, firefighting, and medical personnel present, they should also record the time of arrival and departure, and the vehicle number; if the trapped person has an injured person, the situation of the injured person and the hospital to which they were sent should be recorded.
10. The manager of the maintenance unit or the personnel on duty shall record the time, cause, rescue method and repair time of the failure in detail.
2. In the absence of any notice and sudden power outage, the maintenance unit shall immediately confirm whether it is an internal fault power outage or an external power outage. If it is an internal fault and power failure, immediately send someone to find out the cause and take measures to prevent the fault from expanding. If it is an external power failure, on the one hand, it is necessary to prevent accidents caused by sudden calls; on the other hand, it is necessary to call the power bureau to inquire about the power failure, find out when to restore the power supply, and notify the management and operation department of the information.
4. Arrange employees to the main entrances and exits of the community and the elevator hall to maintain order, strengthen security measures, strictly prevent people from creating chaos, fish in troubled waters, and close the gate when necessary.
5. Preventive measures for sudden power failure:
1) The maintenance unit should check the emergency lighting and emergency broadcasting system frequently to ensure normal operation.
2) The management department shall remind office residents and merchants to prepare some emergency lights or candles to prevent power failure.
3) The security department and maintenance units shall be equipped with portable emergency lighting lamps in addition to torches for patrol and maintenance, which shall be charged and maintained from time to time and kept in good condition.
Article Source: Network
If there is infringement, contact Li delete
Keywords:
AVIC Elevator Equipment, AVIC Elevator, Elevator Sales, AVIC Elevator Sales, Elevator Maintenance